Implementation
Type | Output voltage |
Output current |
ZI-22 | 12V DC | 2,5A |
ZI-24 | 24V DC | 1,25A |
Attention!
* Below 160V input power supply voltage will continue to stabilize the output voltage, but the maximum output current will decrease concurrent with a decline in input voltage.
* Due to the high frequency converter, some very sensitive radio or microprocessor can operate correctly. It is recommended that you install the filter OP-230 (see item 18) between the power supply and receiver.
* By increasing the load above Imax will stabilize power supply current, but output voltage will decrease. If a outputvoltage falls to about 40% of the power supply is switched off and will be 1.5 ÷ 2sec. sample. Similarly happens when you connect the receiver, which receives a large current boot (ie the cold light bulb). If you’re experiencing is not too large, the power supply after a few attempts (eg, the gradual warming-up, the light bulb filaments) runs. If the load is too large to sample the power supply will disconnect the load moment.