The most important functions
- Miniature size, weight and the possibility of mounting on a DIN rail.
- Sensorless vector motor control and control based on freely programmable V / F characteristics.
- Overload capacity up to 150% for one minute. PLC mode with the possibility of programming up to 16 steps (speed, acceleration and deceleration time, duration) performed once or cyclically by the inverter.
- The built-in RS-485 communication module supporting the Modbus RTU protocol allows the inverter to be connected to industrial networks and remote control, supervision and configuration of the inverter operation.
- Built-in PID controller. High flexibility in programming the inverter inputs and outputs. Possibility to limit access to settings and secure with a PIN number.
Types
Inverter type | Input voltage | Input current | Output voltage | Output current | Maximum engine power | Length
L |
Width
W |
Height
H |
V | A | V | A | kW | mm | mm | Mm | |
FA-1LS-004 | 1 x 230 | 5,4 | 3 x 230 | 2,5 | 0,4 | 138 | 72 | 123,5 |
FA-1LS-007 | 1 x 230 | 8,2 | 3 x 230 | 4,0 | 0,7 | |||
FA-1LS-015 | 1 x 230 | 14,0 | 3 x 230 | 7,0 | 1,5 | |||
FA-1LS-022 | 1 x 230 | 23,0 | 3 x 230 | 10,0 | 2,2 | 185 | 134 | |
FA-3HS-007 | 3 x 400 | 4,3 | 3 x 400 | 2,5 | 0,7 | 138 | 123,5 | |
FA-3HS-015 | 3 x 400 | 5,0 | 3 x 400 | 3,8 | 1,5 | |||
FA-3HS-022 | 3 x 400 | 5,8 | 3 x 400 | 5,1 | 2,2 | |||
FA-3HS-040 | 3 x 400 | 10,5 | 3 x 400 | 9,0 | 4,0 | 185 | 134 | |
FA-3HS-055 | 3 x 400 | 14,6 | 3 x 400 | 13,0 | 5,5 |