Made:
Little, easy to mount light dependent sensor with 1 meter cable 2×0,5mm² with posibility to extend (connection of leads should be made in hermetic distribution box or at a place free from atmospheric influence
Attention!
The external probe should be situated at place with permanent access to day light, which, due to its changes of intensity, will cause switching ON and OFF the lighting.
When length of connecting cable of external probe exceeds 10m it should not be laid in vicinity of a parallel conductor under mains voltage, or conducting great currents. In any case always connect correctly phase and neutral leads to the light dependent relay.
Tips
Correct assembly
Make sure that the switched light source does not illuminate the twilight sensor. Otherwise, it may lead to accidental switching on and off of the light source. Extending the probe cables If it is necessary to extend the external probe cable, use a two-core cable with a cross-section of no less than 0.5 mm2 and a length of no more than 10 m.Cable routingThe external probe cable should not be routed parallel to the power cables, e.g. in one tube.