Functioning
Functions:
* DELAYED OFF – CYCLIC
Until the relay is switched on, the contacts remain in positions 2-3 and 11-10. After applying the supply voltage, the contacts are switched to positions 2-1 and 11-12 for time t1. After measuring the time t1, the contacts return to positions 2-3 and 11-10 for the time t2. The sequence of these switching is carried out cyclically.
* DELAYED ANNOUNCEMENT – CYCLIC
After applying the supply voltage, the contacts remain in position 2-3 and 11-10 for time t1. After measuring the time t1, the contacts are switched to positions 2-1 and 11-12 for the time t2. After time t2, relay contacts return to positions 2-3 and 11-10. The sequence of these switching is carried out cyclically.
Attention!
* When the power is turned on, the system does not react to changing the time range settings.
* Work with the newly set time range occurs after switching off and restarting the power supply.
* With the power supply switched on within the set time range, it is possible to smoothly adjust the time in the range of the time setting value.